… of Point-of-Care Transesophageal Echocardiography in the Intensive Care Unit for Detecting the Cause of Hemolytic Anemia After Ascending Aorta Replacement

Y Oshima, Y Seino, S Takagi, M Yamamoto… - … of Cardiothoracic and …, 2021 - Elsevier
… Most commonly, hemolysis after type A aortic dissection repair occurs in a delayed fashion,
… , hemolysis after ascending aortic replacement can occur due to inversion of Teflon felt strips

[HTML][HTML] Hemolytic anemia caused by kinked graft 6 months after aortic dissection repair

K Tamura, W Tatsuishi, Y Konishi, N Konno… - Journal of …, 2022 - Springer
replacement of the ascending aorta and a root repair for type … stenosis is mainly due to the
inversion of inner felt strips (50%) … hemolytic anemia due to graft kinking because no inner felt

Hemolytic Anemia Occurring 14 Years after Ascending Aortic Replacement for Acute Type A Aortic Dissection Due to Aortic Pseudoaneurysm Derived from …

K Izaki, Y Kawai, K Kobayashi, T Itoh… - Annals of Vascular …, 2023 - jstage.jst.go.jp
… Moreover, the ascending aortainversion of the inner felt strip used for anastomosis was
the most common, and only six cases were attributed to external compression, which was due to

Hemolytic Anemia Caused by Kinked Graft 6 Months After Aortic Dissection Repair: A Case Report

K Tamura, W Tatsuishi, Y Konishi, N Konnno, Y Katou… - 2022 - researchsquare.com
replacement of the ascending aorta and a root repair for type … stenosis is mainly due to the
inversion of inner felt strips (50%) … hemolytic anemia due to graft kinking because no inner felt

[HTML][HTML] Patient-specific stent for hemolytic anemia due to a kinked ascending aortic graft

J Lee, HA Lim, SB Hong, YH Kim… - Journal of Thoracic …, 2023 - ncbi.nlm.nih.gov
… , who underwent ascending aorta replacement for acute type A aortic dissection 7 years ago,
… , but also by rare occurrences such as a folded elephant trunk or an inverted felt strip (1,2). …

Simultaneous aortic valve-in-valve and ascending stent grafting for prosthetic valve Stenosis and ascending flap

Y Yamashita, K Shimamura, K Maeda… - Annals of Vascular …, 2020 - jstage.jst.go.jp
repair for a diseased aortic valve and the ascending aorta is … aortic valve stenosis and
internal bovine pericardial flap after … using an inverted bovine pericardium and outer felt strip. …

[HTML][HTML] Hemolytic anemia caused by an excessively kinked prosthetic graft after total arch replacement detected by 4-dimensional flow magnetic resonance imaging …

Y Takei, I Shibasaki, K Suzuki, S Miyazaki, S Hirota… - Medicine, 2022 - journals.lww.com
… a previously reported technique for Stanford type A aortic dissection. [ 4 ] The patient visited
… of 2 main causes: anastomotic site stenosis with inverted internal felt strips and graft kinking. …

Four‐dimensional flow magnetic resonance imaging is useful for assessing hemolytic anemia following surgical repair of type A aortic dissection

K Takahashi, T Sekine, J Kurita… - Journal of Cardiac …, 2022 - Wiley Online Library
hemolytic anemia after emergency ascending aortic … stenosed proximal anastomosis of a
replaced ascending aorta. … was stenosed owing to inversion of the inner felt strip (Figure 2). …

Hemolytic Anemia After an Aortic Dissection Treated With a Valve-Sparing Aortic Root Replacement

D de Castro, JE de Villarreal-Soto, EC Ríos, S Lozano… - Case Reports, 2023 - jacc.org
… an inverted Teflon felt strip 1 or a kinked prosthetic graft are the main causes of HA after aortic
… of the entry tear in the ascending aorta and arch, is recommended in patients undergoing …

[HTML][HTML] … emergency redo surgery for acute type A aortic dissecting aneurysm of ascending and aortic arch with frozen elephant trunk following aortic root replacement

YI Lok, J Villaquiran, J Kuo - Journal of Cardiothoracic Surgery, 2024 - Springer
… Teflon strips with interrupted 3 − 0 Prolene mattress sutures … arch replacement with FET
surgery for acute aortic dissection. … the distal aortic stump with Teflon felt when anastomose to …